1.General Introduction

ABB 266AST absolute pressure transmitter is a traditional type for gauge pressure measurement, measure range from 0Kpa to 60Mpa, maximum static pressure is up to 90Mpa and maximum turn down ratio up to 100:1, standard accuracy is 0.04%, maximum accuracy 0.025% is optional, meets SIL2,SIL3 safety applications as per IEC 61508 standard. Accordingly to customer requests, it can be integrated to two way M26 manifold, or remote connection to manifold via impulse line.

2.Measuring Span & Range Limits

Sensor Code

Lower Range Limit (LRL)

Upper Range Limit (URL)

Standard TD Ratio

Max. TD Ratio

Proof Pressure

C

0

6Kpa, 60mbar, 24inH2O

10:1

20:1

1Mpa, 10bar, 145psi

F

0

40Kpa, 400mbar, 160inH2O

10:1

20:1

1Mpa, 10bar, 145psi

L

0

250Kpa, 2500mbar, 1000inH2O

10:1

20:1

3Mpa, 30bar, 435psi

D

0

1000Kpa, 10bar, 145psi

10:1

20:1

6Mpa, 60bar, 870psi

U

0

3000Kpa, 30bar, 450psi

10:1

20:1

6Mpa, 60bar, 870psi

R

0

10000Kpa, 100bar, 1450psi

10:1

20:1

30Mpa, 300bar, 5945psi


3.Ambient & Process Temperature Limits

Oil filling & sensor range

Ambient temperature limits

Process temperature limits

Silicone oil

-40 and 85℃  (-40   and 185℉)

-50 and 121℃  (-58   and 250℉)

Fluorocarbon (Galden)

-40 and 85℃  (-40   and 185℉)

-40 and 121℃  (-40   and 250℉)

White oil

-6 and 85℃  (21 and   185℉)

-6 and 121℃  (-40   and 250℉)

With LCD integral display

-40 and 85℃  (-40   and 185℉)

N/A


4.Basic Code Selection of 266AST Absolute Pressure Transmitter

Main Code

Suffix Codes

Description

266AST










Gauge pressure transmitter – Base accuracy 0.04 %

SENSOR - Span Limits

C









0.2 and 6 kPa   (2 and 60 mbar, 0.8 and 24 in. H2O) 1 MPa (10 bar, 145 psi)

F









0.4 and 40 kPa   (4 and 400 mbar, 1.6 and 160 in. H2O) 1 MPa (10 bar, 145 psi)

L









2.5 and 250   kPa (25 and 2500 mbar, 10 and 1000 in. H2O) 3 MPa (30 bar, 435 psi)

D









10 and 1000   kPa (0.1 and 10 bar, 1.45 and 145 psi) 6 MPa (60 bar, 870 psi)

U









30 and 3000   kPa (0.3 and 30 bar, 4.35 and 435 psi) 6 MPa (60 bar, 870 psi)

R









100 and 10000   kPa (1 and 100 bar, 14.5 and 1450 psi) 30 MPa (300 bar, 4350 psi)

Diaphragm Material/   Filling Fluid


S








Stainless   steel AISI 316L (1.4435) Silicone oil (Only available with flush diaphragm)   NACE


K








Hastelloy®   C-276 Silicone oil NACE


A








Stainless   steel AISI 316L (1.4435) Fluorocarbon - Galden NACE


F








Hastelloy®   C-276 Fluorocarbon - Galden (suited to oxygen applications) NACE


G








Hastelloy®   C-276 gold-plated Silicone oil NACE


E








Hastelloy®   C-276 gold plated Fluorocarbon - Galden (suited to oxygen applications)


6








Stainless   steel AISI 316L (1.4435) White oil (FDA) (Only available with flush   diaphragm)


Z








Hastelloy®   C-276 White oil (FDA) NACE

Process Connection   Material / Type



B







Stainless   steel AISI 316L (1.4404) 1/2-14 NPT internal thread NACE



P







Stainless   steel AISI 316L (1.4404) DIN EN 837-1 G 1/2 B NACE



S







Stainless   steel AISI 316L (1.4404) DIN EN 837-1 G 1/2 B NACE



T







Stainless   steel AISI 316L (1.4404) 1/2-14 NPT male thread NACE



E







Hastelloy®   C-276 1/2-14 NPT internal thread NACE



D







Hastelloy®   C-276 DIN EN 837-1 G 1/2 B NACE



K







Hastelloy®   C-276 1/2-14 NPT male thread NACE

Gasket Material




N






None

Housing Material/   Electrical Connection





A





Aluminium   alloy (Barrel type) 1/2-14 NPT





B





Aluminium   alloy (Barrel type) M20 x 1.5





E





Aluminium   alloy (Barrel type) Harting Han plug connector





G





Aluminum alloy   (Barrel type) / Fieldbus connector (General purpose only)





S





Stainless   steel (barrel type) 1/2-14 NPT (I2 or I3 required)





T





Stainless   steel (barrel type) M20 x 1.5 (I2 or I3 required)





J





Aluminium   alloy (DIN type) M20 x 1.5





K





Aluminium   alloy (DIN type) Harting Han plug connector (General purpose only)





W





Aluminium   alloy (DIN type) Fieldbus plug connector (General purpose only)





Z





Stainless   steel (barrel type) Fieldbus plug connector (General purpose only)

Output






1




HART digital   communication and 4 to 20 mA






2




Profibus PA






3




Foundation   fieldbus






8




HART digital   communication and 4 to 20 mA, SIL2 and SIL3 certified to IEC 61508

Explosion Protection   Certification







E1



ATEX Intrinsic   Safety Ex ia







E2



ATEX Explosion   Proof Ex db







E3



ATEX Intrinsic   Safety Ex ic







E4



FM approval   (Canada) (Only available with 1/2-14 NPT or M20 electrical connections)







E6



FM approval   (USA) (Only available with 1/2-14 NPT or M20 electrical connections)







EA



FM approvals   (USA and Canada) Intrinsic Safety







EB



FM approvals   (USA and Canada) Explosion Proof







EC



FM approvals   (USA and Canada) Nonincendive







EN



Combined ATEX,   IECEx and FM approvals (USA and Canada)







EW



Combined ATEX   Ex ia, Ex db and Ex ic







EB



IECEx Intrinsic   Safety Ex ia







E9



IECEx   Explosion Proof Ex db







ER



IECEx   Intrinsic Safety Ex ic







EH



Combined IEC   Approval Ex ia and Ex db







EI



Combined IEC   Approval Ex ia, Ex db and Ex ic







EY



NEPSI   Intrinsic Safety Ex ia







EZ



NEPSI   Explosion Proof Ex d







ES



NEPSI   Intrinsic Safety Ex ic







EP



Combined NEPSI   Ex ia and Ex d







EQ



Combined NEPSI   Ex ia, Ex d and Ex ic

Other Explosion   Protection Certifications








W1


TR CU EAC Ex   ia Russia (incl. GOST Metrologic Approval)








W2


TR CU EAC Ex d   Russia (incl. GOST Metrologic Approval)








W3


TR CU EAC Ex   ia Kazakhstan (incl. GOST Metrologic Approval)








W4


TR CU EAC Ex d   Kazakhstan (incl. GOST Metrologic Approval)








WF


TR CU EAC Ex   ia Belarus (incl. GOST Metrologic Approval)








WG


TR CU EAC Ex d   Belarus (incl. GOST Metrologic Approval)

Integral LCD Display









L1

With integral   LCD display









L5

With integral   touch screen LCD display (TT G)

Optional Codes

/Optional   codes

5.Basic Code Selection of M26 Manifolds

Main Code

Suffix Codes

Description

M26















Manifold model for 266   Pressure Transmitters

Design

D














Manifold for DP   Style transmitters

P














Manifold for P   Style transmitters

Revision


A













Revision A

Body configuration



S












Standard construction



V












For vertical-flange   transmitter

Valves




2











Two-valve   manifold




3











Three-valve   manifold




5











Five-valve   manifold

Valve Type





V










Standard

Material (wetted parts)






S









AISI   316L SS, NACE






H









Hastelloy   C276, NACE






M









Monel   400






N









Inconel   625

Packing material







P








PTFE







G








Graphoil

Gasket material   (wetted parts)








N







None








P







PTFE








G







Graphoil

Manifold process   connection (INLET)









F






Threaded 1/2 in. - 14   NPT-female









M






Threaded 1/2 in. - 14   NPT-male

Manifold   transmitter connection (OUTLET)










1





Flanged outlet   according to IEC61518/B










F





Threaded 1/2 in. - 14   NPT-female










M





Threaded 1/2 in. - 14   NPT-male

Rating











6




413.7 bar (41.37MPa,   6000 psi)











1




690 bar (69MPa, 10000   psi)

Transmitter   fixing bolts












N



None












C



Carbon Steel












S



Stainless Steel NACE   compliant (MWP=21MPa, 210 bar, 3045 psi)

Bracket kit













N


None













C


Carbon Steel













S


Stainless Steel NACE   compliant (MWP=21MPa, 210 bar, 3045 psi)

Material   traceability














2

Inspection certificate   EN 10204–3.1 of process wetted parts

Optional codes

/Optional codes