Main Code
|
Suffix Codes
|
Description
|
266AST
|
|
|
|
|
|
|
|
|
|
Gauge pressure transmitter – Base accuracy 0.04 %
|
SENSOR - Span Limits
|
C
|
|
|
|
|
|
|
|
|
0.2 and 6 kPa (2 and 60 mbar, 0.8 and 24 in. H2O) 1 MPa (10 bar, 145 psi)
|
F
|
|
|
|
|
|
|
|
|
0.4 and 40 kPa (4 and 400 mbar, 1.6 and 160 in. H2O) 1 MPa (10 bar, 145 psi)
|
L
|
|
|
|
|
|
|
|
|
2.5 and 250 kPa (25 and 2500 mbar, 10 and 1000 in. H2O) 3 MPa (30 bar, 435 psi)
|
D
|
|
|
|
|
|
|
|
|
10 and 1000 kPa (0.1 and 10 bar, 1.45 and 145 psi) 6 MPa (60 bar, 870 psi)
|
U
|
|
|
|
|
|
|
|
|
30 and 3000 kPa (0.3 and 30 bar, 4.35 and 435 psi) 6 MPa (60 bar, 870 psi)
|
R
|
|
|
|
|
|
|
|
|
100 and 10000 kPa (1 and 100 bar, 14.5 and 1450 psi) 30 MPa (300 bar, 4350 psi)
|
Diaphragm Material/ Filling Fluid
|
|
S
|
|
|
|
|
|
|
|
Stainless steel AISI 316L (1.4435) Silicone oil (Only available with flush diaphragm) NACE
|
|
K
|
|
|
|
|
|
|
|
Hastelloy® C-276 Silicone oil NACE
|
|
A
|
|
|
|
|
|
|
|
Stainless steel AISI 316L (1.4435) Fluorocarbon - Galden NACE
|
|
F
|
|
|
|
|
|
|
|
Hastelloy® C-276 Fluorocarbon - Galden (suited to oxygen applications) NACE
|
|
G
|
|
|
|
|
|
|
|
Hastelloy® C-276 gold-plated Silicone oil NACE
|
|
E
|
|
|
|
|
|
|
|
Hastelloy® C-276 gold plated Fluorocarbon - Galden (suited to oxygen applications)
|
|
6
|
|
|
|
|
|
|
|
Stainless steel AISI 316L (1.4435) White oil (FDA) (Only available with flush diaphragm)
|
|
Z
|
|
|
|
|
|
|
|
Hastelloy® C-276 White oil (FDA) NACE
|
Process Connection Material / Type
|
|
|
B
|
|
|
|
|
|
|
Stainless steel AISI 316L (1.4404) 1/2-14 NPT internal thread NACE
|
|
|
P
|
|
|
|
|
|
|
Stainless steel AISI 316L (1.4404) DIN EN 837-1 G 1/2 B NACE
|
|
|
S
|
|
|
|
|
|
|
Stainless steel AISI 316L (1.4404) DIN EN 837-1 G 1/2 B NACE
|
|
|
T
|
|
|
|
|
|
|
Stainless steel AISI 316L (1.4404) 1/2-14 NPT male thread NACE
|
|
|
E
|
|
|
|
|
|
|
Hastelloy® C-276 1/2-14 NPT internal thread NACE
|
|
|
D
|
|
|
|
|
|
|
Hastelloy® C-276 DIN EN 837-1 G 1/2 B NACE
|
|
|
K
|
|
|
|
|
|
|
Hastelloy® C-276 1/2-14 NPT male thread NACE
|
Gasket Material
|
|
|
|
N
|
|
|
|
|
|
None
|
Housing Material/ Electrical Connection
|
|
|
|
|
A
|
|
|
|
|
Aluminium alloy (Barrel type) 1/2-14 NPT
|
|
|
|
|
B
|
|
|
|
|
Aluminium alloy (Barrel type) M20 x 1.5
|
|
|
|
|
E
|
|
|
|
|
Aluminium alloy (Barrel type) Harting Han plug connector
|
|
|
|
|
G
|
|
|
|
|
Aluminum alloy (Barrel type) / Fieldbus connector (General purpose only)
|
|
|
|
|
S
|
|
|
|
|
Stainless steel (barrel type) 1/2-14 NPT (I2 or I3 required)
|
|
|
|
|
T
|
|
|
|
|
Stainless steel (barrel type) M20 x 1.5 (I2 or I3 required)
|
|
|
|
|
J
|
|
|
|
|
Aluminium alloy (DIN type) M20 x 1.5
|
|
|
|
|
K
|
|
|
|
|
Aluminium alloy (DIN type) Harting Han plug connector (General purpose only)
|
|
|
|
|
W
|
|
|
|
|
Aluminium alloy (DIN type) Fieldbus plug connector (General purpose only)
|
|
|
|
|
Z
|
|
|
|
|
Stainless steel (barrel type) Fieldbus plug connector (General purpose only)
|
Output
|
|
|
|
|
|
1
|
|
|
|
HART digital communication and 4 to 20 mA
|
|
|
|
|
|
2
|
|
|
|
Profibus PA
|
|
|
|
|
|
3
|
|
|
|
Foundation fieldbus
|
|
|
|
|
|
8
|
|
|
|
HART digital communication and 4 to 20 mA, SIL2 and SIL3 certified to IEC 61508
|
Explosion Protection Certification
|
|
|
|
|
|
|
E1
|
|
|
ATEX Intrinsic Safety Ex ia
|
|
|
|
|
|
|
E2
|
|
|
ATEX Explosion Proof Ex db
|
|
|
|
|
|
|
E3
|
|
|
ATEX Intrinsic Safety Ex ic
|
|
|
|
|
|
|
E4
|
|
|
FM approval (Canada) (Only available with 1/2-14 NPT or M20 electrical connections)
|
|
|
|
|
|
|
E6
|
|
|
FM approval (USA) (Only available with 1/2-14 NPT or M20 electrical connections)
|
|
|
|
|
|
|
EA
|
|
|
FM approvals (USA and Canada) Intrinsic Safety
|
|
|
|
|
|
|
EB
|
|
|
FM approvals (USA and Canada) Explosion Proof
|
|
|
|
|
|
|
EC
|
|
|
FM approvals (USA and Canada) Nonincendive
|
|
|
|
|
|
|
EN
|
|
|
Combined ATEX, IECEx and FM approvals (USA and Canada)
|
|
|
|
|
|
|
EW
|
|
|
Combined ATEX Ex ia, Ex db and Ex ic
|
|
|
|
|
|
|
EB
|
|
|
IECEx Intrinsic Safety Ex ia
|
|
|
|
|
|
|
E9
|
|
|
IECEx Explosion Proof Ex db
|
|
|
|
|
|
|
ER
|
|
|
IECEx Intrinsic Safety Ex ic
|
|
|
|
|
|
|
EH
|
|
|
Combined IEC Approval Ex ia and Ex db
|
|
|
|
|
|
|
EI
|
|
|
Combined IEC Approval Ex ia, Ex db and Ex ic
|
|
|
|
|
|
|
EY
|
|
|
NEPSI Intrinsic Safety Ex ia
|
|
|
|
|
|
|
EZ
|
|
|
NEPSI Explosion Proof Ex d
|
|
|
|
|
|
|
ES
|
|
|
NEPSI Intrinsic Safety Ex ic
|
|
|
|
|
|
|
EP
|
|
|
Combined NEPSI Ex ia and Ex d
|
|
|
|
|
|
|
EQ
|
|
|
Combined NEPSI Ex ia, Ex d and Ex ic
|
Other Explosion Protection Certifications
|
|
|
|
|
|
|
|
W1
|
|
TR CU EAC Ex ia Russia (incl. GOST Metrologic Approval)
|
|
|
|
|
|
|
|
W2
|
|
TR CU EAC Ex d Russia (incl. GOST Metrologic Approval)
|
|
|
|
|
|
|
|
W3
|
|
TR CU EAC Ex ia Kazakhstan (incl. GOST Metrologic Approval)
|
|
|
|
|
|
|
|
W4
|
|
TR CU EAC Ex d Kazakhstan (incl. GOST Metrologic Approval)
|
|
|
|
|
|
|
|
WF
|
|
TR CU EAC Ex ia Belarus (incl. GOST Metrologic Approval)
|
|
|
|
|
|
|
|
WG
|
|
TR CU EAC Ex d Belarus (incl. GOST Metrologic Approval)
|
Integral LCD Display
|
|
|
|
|
|
|
|
|
L1
|
With integral LCD display
|
|
|
|
|
|
|
|
|
L5
|
With integral touch screen LCD display (TT G)
|
Optional Codes
|
/Optional codes
|